Between The Lines
Does the leveling of the refrigerator really matter? Why yes… yes it does. As a matter of fact it’s the most important aspect of all. The ammonia absorption cooling unit operates utilizing a bubble pump similar to that of a percolator coffee pot. Just as with a percolator coffee pot, if you were to hold it at an angle while trying to brew coffee you would be quite disappointed with the end result. The bubble pump operates most efficiently in a completely vertical position that allows the liquid escaping from the top of the inner tube to be pulled back down to the reservoir where it will be incorporated again into the supply of refrigerant. Keeping the